Network structures
6.3 Spanning Tree
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
260 Configuration Manual, 06/2016, C79000-G8976-C252-11
The parameters have the following meaning:
Parameter
Description
cost
Keyword for the costs of the port for calculating the lowest-cost path.
disable
Enables the interface for spanning tree.
link-type
Connection status of the following network segment
portfast
Disables the PortFast function.
port-priority
Keyword for the priority of the interface
Note
Configure multiple properties
With each call of the command, you can configure precisely one proper
ty.
If you want to configure several properties, call the command several times.
Result
The selected setting was reset to the default value.
Further notes
You configure the setting with the spanning-tree command (properties).
You display these settings and other information with the commands that start with
show
spanning tree ...
.
6.3.5.3
spanning-tree mst
Description
With this command, you configure the various properties of the Multiple Spanning Tree
function:
With the
cost option, you configure the port costs used to calculate the lowest-cost path.
With the
port-priority option, you configure the priority of the interface for negotiating a
Multiple Spanning Tree configuration.
With the
disable option, you disable the interface for the Multiple Spanning Tree function.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals