System time
5.1 System time setting
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
158 Configuration Manual, 06/2016, C79000-G8976-C252-11
Syntax
Call up the command with the following parameters:
time set hh:mm:ss <day (1-31)>
{january|february|march|april|may|june|july|august|september|october|november|decembe
r}
<year (2000 - 2035)>
The parameters have the following meaning:
Parameter
Description
Range of values / note
hh:mm:ss
Time of day Hour, minute, second each sepa-
rated by ":" no link
day
Day of the month
1 ... 31
- Month january, february, march, april,
may, june, july, august, septem-
ber, october, november, decem-
ber
year
Year
2000 ... 2035
Result
The system time is set.
Further notes
You display the settings for the system clock with the show time command.
5.1.2.3
time dst date
Description
With this command, you configure the start and end of daylight saving time.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals