Layer 2 management protocols
8.8 MLD Snooping (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
502 Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ipv6 mld join ratelimit <value(100-1000)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
value
Number of Join messages 100-1000
Default: 0
Result
The maximum number is defined.
Further notes
You delete das limit for Join-messages on the device with the no ipv6 mld join ratelimit
command.
You can display the status of this function and other information with the
show ipv6 mld
snooping globals
command.
8.8.2.2
no ipv6 mld join ratelimit
Description
With this command, you delete the limit for Join messages on the device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
no ipv6 mld join ratelimit

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals