System time
5.3 SNTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
168 Configuration Manual, 06/2016, C79000-G8976-C252-11
Result
You are now in the SNTP configuration mode.
The command prompt is as follows:
cli(config-sntp)#
Further notes
You exit the SNTP configuration modewith the end or exit command.
5.3.3
Commands in the SNTP configuration mode
This section describes commands that you can call up in the SNTP configuration mode.
In the Global configuration mode, enter the
sntp command to change to this mode.
If you exit the SNTP configuration mode with the
exit command, you return to the Global
configuration mode.
If you exit the SNTP configuration mode with the
end command, you return to the
Privileged EXEC mode.
5.3.3.1
sntp client addressing-mode
Description
With this command, you configure the addressing mode of the SNTP client as unicast or
broadcast.
Requirement
The SNTP client is activated.
You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp client addressing-mode{unicast|broadcast}

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals