Network structures
6.1 VLAN
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
202 Configuration Manual, 06/2016, C79000-G8976-C252-11
Call up the command with the following parameters:
private-vlan mapping [{add | remove}] <vlan-list>
The parameters have the following meaning:
Removes secondary PVLANs. -
VLAN ID of the secondary PVLAN Separate the PVLANs with commas
if you specify several PVLANs.
The IP interface of the primary PVLAN can be reached from the selected secondary
PVLANs.
You delete the link between secondary PVLANs and the IP interface of the primary PVLAN
with the command
no private-vlan mapping.
You display this setting with the
show interfaces command with the private-vlan mapping
parameter.
no private-vlan mapping
Description
With this command you delete the link between secondary PVLANs and the IP interface of
the primary PVLAN with the command .
● The interface is configured as an IP interface.
● You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Call the command without parameter assignment:
no private-vlan mapping