Diagnostics
12.3 Loop detection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
921
Syntax
Call the command without parameters:
loopd reaction remote
Result
"disable" is activated for the loopd reaction remote function.
"disable" is the default after enabling loop detection.
Further notes
You enable the "no action" reaction with the no loopd reaction remote command.
You can display the status of this function and other information with the
show loopd
command.
12.3.3.7
no loopd reaction remote
Description
With this command, you enable the "no action" reaction for a remote loop. If a remote loop is
detected, this has no effect on the port.
Requirement
loopd is enabled
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no loopd reaction remote
Result
"no action" is activated for the loop reaction remote function.
"disable" is the default after enabling loop detection.
Further notes
You enable the "disable" setting with the loopd reaction remote command.
You can display the status of this function and other information with the
show loopd
command.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals