Network protocols
7.6 DHCPv4 Relay Agent (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
374 Configuration Manual, 06/2016, C79000-G8976-C252-11
Result
The Circuit ID is assigned.
Further notes
You remove the Circuit ID with the no ip dhcp relay circuit-id command.
You display the IP addresses with the
show dhcp server command.
You display the settings with the
show ip dhcp relay information command.
7.6.3.2
no ip dhcp relay circuit-id
Description
With this command, you remove the Circuit ID.
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call the command without parameter assignment:
no ip dhcp relay circuit-id
Result
The Circuit ID is removed.
Further notes
You configure the Circuit ID with the ip dhcp relay circuit-id command.
You display the IP addresses with the
show dhcp server command.
You display the settings with the
show ip dhcp relay information command.
7.6.3.3
ip dhcp relay remote-id
Description
With this command, you specify the device ID.