Page #117 background image
Configuration
3.2 Load and Save
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
117
Further notes
You enable the password for the user certificate with the password command.
3.2.5.4
tftp filename
Description
With this command, you assign a name to a file type.
The file type decides the type that is affected by the
tftp load or tftp save action. The
name decides the file to be copied to or from the TFTP server.
Requirement
You are in the LOADSAVE configuration mode.
The command prompt is as follows:
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
tftp filename {showfiles|filetype< filetype >name<filename>}
The parameters have the following meaning:
Parameter
Description
Range of values / note
showfiles
Shows the available files
-
filetype
Keyword for a file type to be assigned
a name
-
filetype
Name of the file type
max. 100 characters
name
Keyword for a file name to be assigned
to the file type
-
filename
Name of the file
max. 100 characters
Result
The file types are displayed or the file type is assigned a name.
Further notes
With the "show loadsave files" command, you can display the file types.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals