Configuration
3.2 Load and Save
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
118 Configuration Manual, 06/2016, C79000-G8976-C252-11
3.2.5.5
tftp load
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by Siemens
can be downloaded to the device.
Description
With this command, you load a file from a TFTP server into the file system of the device. The
TFTP protocol is used for the transfer. You can also display a list of available files.
Requirement
The name of the file is specified
You are in the LOADSAVE configuration mode.
The command prompt is:
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
tftp load{showfiles|filetype<filetype>}
The parameters have the following meaning:
Parameter
Description
Range of values / note
showfiles
Shows the available files
-
filetype
Keyword for a file type to be loaded
-
filetype
Name of the file type
max. 100 characters
Result
The file types are displayed or the file is downloaded to the device.
Further notes
You configure the name of the file with the tftp filename command.
With the "
show loadsave files" command, you can display the file types.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals