Network structures
6.3 Spanning Tree
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
247
Result
The compatibility version of the protocol is selected.
Further notes
You can reset the setting to the default mst with the no spanning-tree compatibility
command.
You can display the status of this function and other information with the
show spanning tree
detail
command.
You can display information about active ports with the
show spanning tree active
command.
6.3.4.4
no spanning-tree compatibility
Description
With this command, you reset the compatibility version of the protocol of the spanning tree
function to the default value.
The default value is MST.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree compatibility
Result
The compatibility version is reset to the default value.
Further notes
You configure the setting with the spanning-tree compatibility command.
You can display the status of this function and other information with the
show spanning tree
detail
command.