Layer 2 management protocols
8.5 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
480 Configuration Manual, 06/2016, C79000-G8976-C252-11
Call up the command with the following parameters:
ring ports <interface-type><interface-id><interface-type><interface-id>
The parameters have the following meaning:
Specifies the interface type for the first ring port
Specifies the number of the interface for the first ring port
Specifies the interface type for the second ring port
Specifies the number of the interface for the second ring port
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
Note
Differing port addresses
The first and second port must be configured on different interfaces.
The ports of the ring redundancy are configured.
standby connection-name
Description
With this command, you assign a name to the standby connection on the device.
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Call up the command with the following parameters:
standby connection-name <string(32)>
The parameter has the following meaning: