Security and authentication
11.7 Port-based Network Access Control (Dot1X)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
871
Further notes
You also need to enable the guest VLAN function for the device. You do this with the dot1x
guest-vlan
command in the Global configuration mode.
You disable the function with the
no dot1x guest-vlan command.
You display this setting and other information with the
show dot1x command.
11.7.3.2
no dot1x guest-vlan
Description
With this command, you disable the guest VLAN function for a port.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no dot1x guest-vlan
Result
The guest VLAN function is disabled for the device.
Further notes
You enable the function with the dot1x guest-vlan command.
You display this setting and other information with the
show dot1x command.
11.7.3.3
dot1x guest-vlan vlan-id
Description
With this command, you configure a guest VLAN for a port.
The port can only be assigned to the VLAN, if the VLAN has been created on the device.
Otherwise Authentication is rejected.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals