Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
561
Syntax
Call up the command with the following parameters:
no ip ospf message-digest-key <Key-ID (0-255)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
Key-ID
ID of the password
Enter a valid ID.
Result
The password is deleted.
Further notes
You specify the password with the ip ospf message-digest-key command.
9.2.4.13
ip ospf retransmit-interval
Description
With this command, you specify the time after which an LSA message is transferred again if
no confirmation has been received.
Note
T
his command is available only with layer 3.
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
ip ospf retransmit-interval <seconds (0 - 3600)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
seconds
Interval in seconds
0 - 3600

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals