Network protocols
7.4 DHCPv6 client (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
341
7.4.2.5
no ipv6 dhcp client option
Description
With this command, you remove the DHCPv6 option classes.
Requirement
DHCPv6 Is activated.
IPv6 is activated
The interface is an IP interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
no ipv6 dhcp client option {user-class | vendor-class | vendor-specific }
The parameters have the following meaning:
Parameter
Description
Range of values / note
user-class
User class
Enter the required user class.
vendor-class
Vendor class
Enter the required vendor class.
vendor-specific
Name of the vendor-specific configuration
Enter the required name.
Result
The required setting is removed.
Further notes
You configure the setting with the ipv6 dhcp client option command.
7.4.2.6
ipv6 dhcp client reconfig-accept
Description
A DHCPv6 server can request a DHCPv6 client to refresh its IPv6 address or configuration
data at any time.
If the option "DHCP reconfig-accept" is set, the DHCPv6 client accepts the reconfiguration
message. This is assuming that it contains the correct reconfiguration key. Via this key, the
DHCP client identifies the DHCPv6 server

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals