System time
5.4 PTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
175
Syntax
Call up the command with the following parameters:
ptp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
+/-hh:mm
The value for the time difference. Hours and minutes specified in
the format +/-HH:MM
Result
The time zone for the Precision Time Protocol is specified.
5.4.2.4
ptp transparent-clock configuration
Description
With this command you change to the PT Transparent Clock configuration mode.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
ptp transparent-clock configuration
Result
You are in the PTP Transparent Clock configuration mode.
The command prompt is as follows:
cli(config-ptp-tc)#