Layer 3 functions
9.3 OSPFv3 (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
593
9.3.3.12
host
Description
With this command, you create an entry in the host table and assign an area ID and / or a
metric to it.
Note
This command is available only with layer 3.
Requirement
You are in the OSPFv3 router configuration mode.
The command prompt is as follows:
cli(config-ospfv3)#
Syntax
Call up the command with the following parameters:
host <IPv6-Address>
{
metric <cost>
} [
area-id {<AreaID>}
]
The parameters have the following meaning:
Parameter
Description
Range of values / note
IPv6-Address
IPv6 address prefix of the host
Enter a valid IPv6 address
metric
Keyword for the metric of the external
standard route.
-
cost
Value of the metric
area-id
Keyword for the area ID
-
AreaID
Area ID Specify the ID in the IPv4 address
format
x.x.x.x = 0 ... 255
0.0.0.0 = backbone area
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
Result
The entry is configured in the host table.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals