Layer 3 functions
9.3 OSPFv3 (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
593
9.3.3.12
host
Description
With this command, you create an entry in the host table and assign an area ID and / or a
metric to it.
Note
This command is available only with layer 3.
Requirement
You are in the OSPFv3 router configuration mode.
The command prompt is as follows:
cli(config-ospfv3)#
Syntax
Call up the command with the following parameters:
host <IPv6-Address>
{
metric <cost>
} [
area-id {<AreaID>}
]
The parameters have the following meaning:
Parameter
Description
Range of values / note
IPv6-Address
IPv6 address prefix of the host
Enter a valid IPv6 address
metric
Keyword for the metric of the external
standard route.
-
cost
Value of the metric
area-id
Keyword for the area ID
-
AreaID
Area ID Specify the ID in the IPv4 address
format
x.x.x.x = 0 ... 255
0.0.0.0 = backbone area
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
Result
The entry is configured in the host table.