EasyManua.ls Logo

Siemens SCALANCE XM-400 - No Snmp V1-V2 Readonly

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network protocols
7.8 SNMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
408 Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
snmp v1-v2 readonly
Result
Write access for SNMPv1 and SNMPv2 PDUs is blocked.
Further notes
You release write access for SNMPv1 and SNMPv2 PDUs with the no snmp v1-v2 readonly
command.
7.8.2.19
no snmp v1-v2 readonly
Description
With this command, you enable write access for SNMPv1 and SNMPv2 PDUs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no snmp v1-v2 readonly
Result
Write access for SNMPv1 and SNMPv2 PDUs is enabled.
Further notes
You block write access for SNMPv1 and SNMPv2 PDUs with the snmp v1-v2 readonly
command.