Layer 3 functions
9.5 VRRPv3 (IPv4 / IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
653
Result
The VRRP3 interface has been deleted.
Further notes
You configure a VRRP3 interface with the interface command.
You display the status and the configuration of the VRRP3 interface with the
show vrrp3 or
show vrrp3 interface command.
9.5.4.3
track interface
Description
With this command, you configure the tracking of interfaces.
When the link of one or more tracked interfaces changes from "up" to "down", the priority of
the assigned VRRP interface is reduced. When the link of the interface changes back from
"down" to "up", the original priority of the VRRP interface is restored.
Note
This command is available only with layer 3.
Requirement
You are in the VRRP Router configuration mode.
The command prompt is as follows:
cli(config-vrrp-v3)#
Syntax
Call up the command with the following parameters:
track <group-index> interface { vlan <vlan-id (1-4094)> | <interface-type>
<interface-id> }
The parameters have the following meaning:
Parameter
Description
Range of values / note
group-index
ID of the interface tracking
-
vlan
Keyword for a VLAN connection
-
vlan-id
Number of the addressed VLAN
1 … 4094
interface-type
Type of interface
Specify a valid interface.
interface-id
Module no. and port no. of the interface
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals