EasyManua.ls Logo

Siemens SCALANCE XM-400 - No Ip Ospf Hello-Interval; Ip Ospf Message-Digest-Key

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
559
9.2.4.10
no ip ospf hello-interval
Description
With this command, you delete the interval.
Note
This command is available only with layer 3.
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameter assignment:
no ip ospf hello-interval
Result
The interval is deleted.
Further notes
You configure the interval with the ip ospf hello-interval command.
You show the configuration of the OSPF interface with the
show ip ospf interface
command.
9.2.4.11
ip ospf message-digest-key
Description
With this command, you specify the password and the ID for authentication with MD5.
Note
This command is available only with layer 3.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Related product manuals