Network structures
6.3 Spanning Tree
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
251
6.3.4.9
no spanning-tree mst instance-id root
Description
With this command, you disable the "root bridge" function on the device.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no spanning-tree mst{instance-id<instance-id(1-64)>}root
The parameters have the following meaning:
Parameter
Description
Range of values / note
instance-id
Keyword for the instance
-
instance-id
Number of the instance
1 ... 64
Result
The "root bridge" function is disabled.
Further notes
You enable the root bridge function with the spanning-tree mst instance-id root command.
You display this setting and other information with the commands that start with
show
spanning tree ...
.
6.3.4.10
spanning-tree passive-listening-compatibility
Description
With this command you enable the "Enhanced Passive Listening Compatibility" function.
If you enable the "Enhanced Passive Listening Compatibility" function, the IE switch sends
topology change frames via the (R)STP edge port that caused the topology change.
Requirement
You are in the Global configuration mode.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals