EasyManuals Logo

Siemens SCALANCE XM-400 Configuration Manual

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
System time
5.4 PTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
174 Configuration Manual, 06/2016, C79000-G8976-C252-11
Syntax
Call the command without parameters:
ptp
Result
The Precision Time Protocol is enabled.
5.4.2.2
no ptp
Description
With this command, you disable the Precision Time Protocol for the device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no ptp
Result
The Precision Time Protocol is disabled.
5.4.2.3
ptp time diff
Description
With this command, you set the time zone for the Precision Time Protocol.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals