System time
5.4 PTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
174 Configuration Manual, 06/2016, C79000-G8976-C252-11
Syntax
Call the command without parameters:
ptp
Result
The Precision Time Protocol is enabled.
5.4.2.2
no ptp
Description
With this command, you disable the Precision Time Protocol for the device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no ptp
Result
The Precision Time Protocol is disabled.
5.4.2.3
ptp time diff
Description
With this command, you set the time zone for the Precision Time Protocol.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#