Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
540 Configuration Manual, 06/2016, C79000-G8976-C252-11
Syntax
Call up the command with the following parameters:
no default-information originate always
[metric <metric-value (0-0xffffff)>]
[metric-type <type (1-2)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
metric
Keyword for the metric of the external
standard route.
--
metric-value
Value of the metric
0-0xffffff
metric-type
Keyword for the type of the external
standard route
--
type
Type of the external route
• 1 - type 1
External and internal costs
• 2 - type 2
External costs
Result
The function is disabled.
Further notes
You enable the function with the default-information originate always command.
9.2.3.17
network area
Description
With this command, you specify an OSPF interface and the Area ID connected to the OSPF
interface.
Note
This command is available only with layer 3.
Requirement
You are in the OSPF Router configuration mode.
The command prompt is as follows:
cli(config-ospf)#

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals