EasyManuals Logo

Siemens SCALANCE XM-400 Configuration Manual

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #560 background imageLoading...
Page #560 background image
Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
560 Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
ip ospf message-digest-key <Key-ID (0-255)> md5 <md5-Key (16)>
The parameters have the following meaning:
Parameter
Description
Range of values / note
Key-ID
ID of the password
0 ... 255
md5
Keyword for the password -
md5-Key
Password for authentication enter a password
Maximum length: 16 characters
Result
The password and the ID are specified.
Further notes
You delete the password with the no ip ospf message-digest-key command.
9.2.4.12
no ip ospf message-digest-key
Description
With this command, you delete the required password.
Note
This command is available only with layer 3.
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals