Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
560 Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
ip ospf message-digest-key <Key-ID (0-255)> md5 <md5-Key (16)>
The parameters have the following meaning:
Parameter
Description
Range of values / note
Key-ID
ID of the password
0 ... 255
md5
Keyword for the password -
md5-Key
Password for authentication enter a password
Maximum length: 16 characters
Result
The password and the ID are specified.
Further notes
You delete the password with the no ip ospf message-digest-key command.
9.2.4.12
no ip ospf message-digest-key
Description
With this command, you delete the required password.
Note
This command is available only with layer 3.
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode.
The command prompt is: