System time
5.4 PTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
172 Configuration Manual, 06/2016, C79000-G8976-C252-11
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IP address
-
ucast_addr
Value for an IPv4 unicast address Enter a valid IPv4 unicast address
fqdn-name
Keyword for a domain name
-
Fully Qualified
Domain Name(100)
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
ipv6
Keyword for an IPv6 address
-
ip6_addr
Value for the IPv6 address of the time
server
Enter a valid IPv6 address.
Result
The SNTP unicast server is reset to the default value.
Further notes
You configure the setting with the sntp unicast-server command.
You display this setting and other information with the
show sntp unicastmode status
command.
5.4
PTP Client
The following devices support time-of-day synchronization using PTP:
SCALANCE XR528-6M
SCALANCE XR552-12M
This section describes commands relevant for configuration of the Precision Time Protocol
according to IEEE 1588.
5.4.1
The "show" commands
This section describes commands with which you display various settings.
5.4.1.1
show ptp info
Description
This command shows the current settings for the Precision Time Protocol (PTP).

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals