Security and authentication
11.7 Port-based Network Access Control (Dot1X)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
881
Further notes
You disable the function with the no dot1x reauthentication command.
You can display the status of this function and other information with the
show
dot1x
command.
11.7.3.16
no dot1x reauthentication
Description
With this command, you disable the function that repeats the authentication of the client by
the authenticator periodically.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no dot1x reauthentication
Result
Periodic authentication is disabled.
Further notes
You enable the function with the dot1x reauthentication command.
You can display the status of this function and other information with the
show
dot1x
command.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals