Layer 2 management protocols
8.5 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
478 Configuration Manual, 06/2016, C79000-G8976-C252-11
8.5.5.6
ring-redundancy standby
Description
With this command, you enable the standby function.
Requirement
HRP is enabled
You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call the command without parameters:
ring-redundancy standby
Result
The standby function is enabled.
Further notes
You disable the setting with the no ring-redundancy standby command.
You can display the status of this function and other information with the
show ring-
redundancy
command.
8.5.5.7
no ring-redundancy standby
Description
With this command, you disable the standby function.
Requirement
HRP is enabled
You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call the command without parameters:
no ring-redundancy standby

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals