Network protocols
7.6 DHCPv4 Relay Agent (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
369
Syntax
Call up the command with the following parameters:
no ip dhcp server <ip address>
The parameter has the following meaning:
Parameter
Description
Range of values / note
ip address
IP address of the DHCP server Enter the IP address to be delet-
ed.
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
Result
The IP address is removed.
Further notes
You enable the DHCP Relay Agent with the service dhcp-relay command.
You create the IP address with the
ip dhcp server command.
You display the IP addresses with the
show dhcp server command.
7.6.2.3
ip dhcp relay circuit-id option
Description
The Circuit ID is a sub option of the "DHCP Relay Information" option. The Circuit ID
contains information about the origin of the DHCP packet.
With this command, you specify the information contained in the Circuit ID.
The Circuit ID is encoded in the DHCP packet if the "DHCP relay information" option is
enabled.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ip dhcp relay circuit-id option [router-index] [vlanid] [recv-port]

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals