Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
130 Configuration Manual, 06/2016, C79000-G8976-C252-11
The user-defined power is compared to the range of values of the class indicated by the
connected device.
If the user-defined power is within the class of the connected device, the user-defined
value is used.
If the user-defined power is above the class of the connected device, the highest value of
the class is used.
If the user-defined power is below the class of the connected device, the lowest value of
the class is used.
If the value used is exceeded, the device is turned off.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
poe pse <integer(1-4)> MaximumPower <integer(1-90)>
The parameters have the following meaning:
Parameter
Description
Range of values / note
integer
Number of the PSE
1 … 4
integer
Value for the maximum power in watts 1 ... 90
Result
The value for the maximum power is configured.
Further notes
You delete the value for the parameter "Maximum Power" with the no poe pse MaximumPower
command.
3.5.2.2
no poe pse MaximumPower
Description
With this command, you delete the value for the "Maximum Power" parameter.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals