Diagnostics
12.3 Loop detection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
919
Result
The blocked port is enabled again.
Further notes
You disable the setting with the no loopd port reset command.
You can display the status of this function and other information with the
show loopd
command.
12.3.3.4
loopd reaction local
Description
With this command, you activate the "disable" reaction for a local loop. If a local loop is
detected, the port is blocked.
Requirement
Loop detection is enabled.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
loopd reaction local
Result
"disable" is activated for the loopd reaction local function.
"disable" is the default after enabling loop detection.
Further notes
You enable the "no action" reaction with the no loopd reaction local command.
You can display the status of this function and other information with the
show loopd
command.