Diagnostics
12.3 Loop detection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
913
The parameters have the following meaning:
Parameter
Description
Range of values / note
interface
Keyword for a an interface description
-
interface-type
Type or speed of the interface Enter a valid interface.
interface-id
Module no. and port no. of the interface
port-channel
Keyword for a port channel connection
-
port-channel-id
Number of the addressed port channel
1 ... 8
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
If you do not select any parameters from the parameter list, the default value is used.
Result
The loop interface is displayed.
Further notes
You can display the status of this function and other information with the show loopd
command.
12.3.2
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.
12.3.2.1
loopd
Description
With this command, you enable the loop detection function.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals