EasyManuals Logo

Siemens SCALANCE XM-400 Configuration Manual

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #910 background imageLoading...
Page #910 background image
Diagnostics
12.2 FMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
910 Configuration Manual, 06/2016, C79000-G8976-C252-11
Syntax
Call up the command with the following parameters:
rmon rx-power [req]<1/10 dBm> [dem]<1/10 dBm>
The parameters have the following meaning:
Parameter
Description
Range of values / note
req
Specify the value at which you are informed of
the deterioration of the received power by a
message of the severity level "Warning"
0 ... -40 dB
The default value depends on the rele-
vant pluggable transceiver.
dem
Specify the value at which you are informed of
the deterioration of the received power by a
message of the severity level "Critical"
0 ... -40 dB
The default value depends on the rele-
vant pluggable transceiver.
Result
The limits for monitoring the received power are defined.
Further notes
You enable this function with the fmp command.
You disable this function with the
no fmp command.
You display the status of this function and other information with the
show fmp stauts and
show fmp limit commands.
You define the limit values for the power loss with the command
fmp power-loss.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals