Configuration
3.3 Reset and Defaults
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
121
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Call up the command with the following parameters:
restart [{factory | pnio | ethernetip | ie}]
The parameters have the following meaning:
without parame-
ters
The system restarts with the cur-
rent configuration
• You can only restart the device with administrator privileges.
• A device should only be restarted by this CLI command or the
corresponding buttons in the WBM and not by a poer cycle on
the device.
Restores the factory settings of the
device and restarts the device.
The factory settings depend on the
device.
• By resetting all the settings to the factory settings, the IP ad-
dress and the passwords are also lost. Following this, the de-
vice can only be accessed via the serial interface, using the
Primary Setup Tool or using DHCP.
• With the appropriate attachment, a previously correctly config-
ured device can cause circulating frames and therefore the
failure of the data traffic.
Restores the default settings of the
PROFINET IO profile and restarts
• The profiles provide a preconfiguration for various use cases of
the devices.
• When you start a device with the default settings of a profile,
the settings are reset to the factory settings and some parame-
ters are set so that they are designed for a use case.
• In contrast to resetting to the factory settings. the users and
passwords are retained after the restart. The configured IP ad-
dress is lost so that device can then only be accessed via the
serial interface, using the Primary Setup Tool or using DHCP.
• With the appropriate attachment, a previously correctly config-
ured device can cause circulating frames and therefore the
failure of the data traffic.
Restores the default settings of the
EtherNet/IP profile and restarts the
Restores the default settings of the
Industrial Ethernet profile and re-
starts the device.
The device is restarted with the selected settings.