Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
525
Requirement
The router is an area border router
You are in the OSPF Router configuration mode.
The command prompt is:
cli(config-ospf)#
Syntax
Call up the command with the following parameters:
area <AreaId> range
<Network>
<Mask>
[{
advertise | notadvertise
}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
AreaId
Area-ID specify an ID.
x.x.x.x
x = 0 ... 255
0.0.0.0 = backbone area
Network
IP address of the address range
specify the IP address
Mask
Subnet mask of the address range
specify the subnet mask.
advertise
The address range is advertised to the
outside. A summary LSA of Type 3 is
generated.
-
notadvertise
The address range is not advertised to
the outside.
-
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
Result
The address range is configured.
Further notes
You delete the address range with the no area range command.
You can display the status of this function and other information with the
show ip ospf -
area-range / summary-address
command.