Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
534 Configuration Manual, 06/2016, C79000-G8976-C252-11
The parameters have the following meaning:
Parameter
Description
Range of values / note
area-id
Area-ID specify a valid ID.
x.x.x.x
x = 0 ... 255
0.0.0.0 = backbone area
router-id
ID of the router
-
authentication
Keyword for the authentication meth-
od of the virtual connection
simple
enables authentication using a
password
messagedigest
enables authentication using
MD5
none
no authentication
hello-interval
Keyword for the interval at which
Hello packets are sent over the virtual
link
-
retransmit-interval
Keyword for the interval after which
packets whose receipt was not con-
firmed are transferred again.
-
transmit-delay
Keyword for the time that a link state
update packet requires for transmis-
sion over the virtual link.
--
dead-interval
Keyword for the interval after which
the neighbor router is classified as
"failed" if Hello packets from it are not
received.
-
authentication-key
Keyword for the unencrypted pass-
word
-
message-digest-key
Keyword for the ID of the password -
key-id
ID of the password. specify the ID
0 ... 255
Result
The virtual link is removed.
Further notes
You create virtual links with the area virtual link command.
You display information about the virtual link with the
show ip ospf virtual command.