EasyManua.ls Logo

Siemens SCALANCE XM-400 - Page 747

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Layer 3 functions
9.9 NAT (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
747
Syntax
Call up the command with the following parameters:
ip nat service <inside local ip> [<inside local port number>]
{ auth | dns | ftp | pop3 | pptp | smtp | telnet | http | nntp | snmp | other
[<inside global port number>]}
[{ tcp | udp | any }] [<description>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
inside local ip
Actual address of the device that
should be reachable from exter-
nal.
Enter a valid IPv4 address.
inside local port
number
Port that will be assigned to the
inside local address.
If you do not specify any ports, the port
that you assign for the
inside global
port number
parameter will be en-
tered.
Service Service for which the port transla-
tion is valid.
auth
dns
ftp
pop3
pptp
smtp
telnet
http
nntp
snmp
other
inside global port
number
Port that will be assigned to the
inside global address.
If you have selected the other service,
you can enter a port.
If you have selected another service, a
port will be specified.
Protocol Protocol for which the port trans-
lation is valid.
tcp
udp
any
description
Description for the port translation
-
Result
The static port translation with a service is configured.
Further notes
You delete a configuration with the no ip nat service command.