Security and authentication
11.1 User management
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
814 Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
user-group <user-group-name> role <role-name> [description <user-group-description>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
user-group
Keyword for a group name
-
user-group-name
Group name Enter the name of the group. The name
must match the group on the RADIUS
server.
The name must meet the following condi-
tions:
It must be unique.
It must be between 1 and 64 charac-
ters long.
role
Keyword for the role name
-
role-name
Role name Enter a role name. Users who are author-
ized with the linked group on the RADIUS
server receive the rights of this role local-
ly on the device.
You can choose between system-defined
and self-defined roles.
description
Keyword for the description
-
user-group-
description
Content of the description Enter a description for the link. The de-
scription text can be up to 100 characters
long.
Result
The group is linked to a role.
Further notes
You delete a link with the no user-group command.
You show the created links with the
show user-groups command.