Page #823 background imageLoading...
Page #823 background image
Security and authentication
11.2 RADIUS client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
823
Syntax
Call up the command with the following parameters:
no radius-server { ipv4 <ipv4-address> | fqdn-name <FQDN> | ipv6 <ipv6-address>}
[primary]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IPv4 address
-
ipv4-address
IPv4 address of the RADIUS server Enter a valid IPv4 address.
fqdn-name
Keyword for a domain name
-
FQDN
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
ipv6
Keyword for an IPv6 address
-
ipv6-address
IPv6 address of the RADIUS server
Enter a valid IPv6 address.
primary
Identifies the RADIUS server as prima-
ry server
-
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 42)".
Result
The entry for a connection between the RADIUS client and a server or the identification as
primary server is deleted.
Further notes
You configure the connection of a RADIUS client to a server with the radius-server
command.
You show the configuration of a RADIUS server on the client with the
show radius server
command.
You show the statistical information of this function with the
show radius statistics
command.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals