Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
898 Configuration Manual, 06/2016, C79000-G8976-C252-11
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Call up the command with the following parameters:
no event config
{cold-warmstart|linkchange|authentication-failure|
rmon-alarm|power-change|rm-state-change|standby-state-change|faultstate-change|
stp-change|vrrp-state-change|loopd-state-change|ospf-state-change|dot1x-port-auth-
state-change|poe- state-change|fmp-state-change|env-data-change|all}
{logtable|syslog|email|trap|faults
|all}
The parameters have the following meaning:
Message if there is cold or warm restart
Message when there is a status change on a physical interface
Message if there is an incorrect login
Message when there is a RMON alarm
Message when there is a status change in the power supply
Message when there is a status change in the redundancy manager
Message when there is a status change on a standby connection
Message when there is a status change in the error monitoring
Message when there is a change in the spanning tree
Message on status change of VRRP routers
Message if there is a status change in the detection of network loops
Message on status change of OSPF
dot1x-port-auth-
state-change
Message when there is a status change in the 802.1X authentication
Message on status change of PoE
Message on status change of FMP
Client that processes the logbook entries
Client that sends the messages to the Syslog server
Client that sends the e-mails
Client that sends the SNMP traps
Error LED lights up. The setting is possible only for a cold or warm restart.
Message when there is a status change in the diagnostics data