Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
898 Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no event config
{cold-warmstart|linkchange|authentication-failure|
rmon-alarm|power-change|rm-state-change|standby-state-change|faultstate-change|
stp-change|vrrp-state-change|loopd-state-change|ospf-state-change|dot1x-port-auth-
state-change|poe- state-change|fmp-state-change|env-data-change|all}
{logtable|syslog|email|trap|faults
|all}
The parameters have the following meaning:
Parameter
Description
cold-warmstart
Message if there is cold or warm restart
linkchange
Message when there is a status change on a physical interface
authentication-
failure
Message if there is an incorrect login
rmon-alarm
Message when there is a RMON alarm
power-change
Message when there is a status change in the power supply
rm-state-change
Message when there is a status change in the redundancy manager
standby-state-
change
Message when there is a status change on a standby connection
faultstate-change
Message when there is a status change in the error monitoring
stp-change
Message when there is a change in the spanning tree
vrrp-state-change
Message on status change of VRRP routers
loopd-state-change
Message if there is a status change in the detection of network loops
ospf-state-change
Message on status change of OSPF
dot1x-port-auth-
state-change
Message when there is a status change in the 802.1X authentication
poe-state-change
Message on status change of PoE
fmp-state-change
Message on status change of FMP
all
All messages
logtable
Client that processes the logbook entries
syslog
Client that sends the messages to the Syslog server
email
Client that sends the e-mails
trap
Client that sends the SNMP traps
faults
Error LED lights up. The setting is possible only for a cold or warm restart.
env-data-change
Message when there is a status change in the diagnostics data
all
All clients at once

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals