Index
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide 1407
code, :AUToscale, 198
code, :CHANnel<n>:LABel, 273
code, :CHANnel<n>:PROBe, 275
code, :CHANnel<n>:RANGe, 282
code, :DIGitize, 204
code, :DISPlay:DATA, 325
code, :DISPlay:LABel, 327
code, :DISPlay:ORDer, 1189
code, :MEASure:PERiod, 500
code, :MEASure:RESults, 493
code, :MEASure:TEDGe, 508
code, :MTESt, 551
code, :POD<n>:THReshold, 587
code, :RUN/:STOP, 224
code, :SYSTem:SETup, 991
code, :TIMebase:DELay, 1229
code, :TIMebase:MODE, 997
code, :TIMebase:RANGe, 999
code, :TIMebase:REFerence, 1000
code, :TRIGger:MODE, 1016
code, :TRIGger:SLOPe, 1035
code, :TRIGger:SOURce, 1036
code, :VIEW and :BLANk, 230
code, :WAVeform, 1112
code, :WAVeform:DATA, 1099
code, :WAVeform:POINts, 1103
code, :WAVeform:PREamble, 1107
code, :WAVeform:SEGMented, 239
code, *RST, 182
code, SCPI.NET library example in
C#, 1386
code, SCPI.NET library example in
IronPython, 1398
code, SCPI.NET library example in Visual
Basic .NET, 1392
code, SICL library example in C, 1366
code, SICL library example in Visual
Basic, 1375
code, VISA COM library example in
C#, 1295
code, VISA COM library example in
Python, 1312
code, VISA COM library example in Visual
Basic, 1286
code, VISA COM library example in Visual
Basic .NET, 1304
code, VISA library example in C, 1319
code, VISA library example in C#, 1338
code, VISA library example in Python, 1359
code, VISA library example in Visual
Basic, 1328
code, VISA library example in Visual Basic
.NET, 1349
colon, root commands prefixed by, 194
color palette for hardcopy, 417
color palette for image, 677
Comma Separated Values (CSV) waveform
data format, 691
command classifications, 1276
command differences from 4000 X-Series
oscilloscopes, 35
command errors detected in Standard Event
Status, 173
Command Expert, 1386
command header, 1277
command headers, common, 1279
command headers, compound, 1279
command headers, simple, 1279
command strings, valid, 1277
commands quick reference, 65
commands sent over interface, 168
commands, more about, 1275
commands, obsolete and
discontinued, 1175
common (*) commands, 3, 165, 168
common command headers, 1279
common logarithm math function, 390
completion criteria for an acquisition, 233,
234
compound command headers, 1279
compound header, 1281
computer control examples, 1285
conditions for external trigger, 339
conditions, reset, 180, 987
conduction calculation method for switching
loss, 646
Config softkey, 44
configurations, oscilloscope, 175, 179,
183, 991
Configure softkey, 44
connect oscilloscope, 43
connect sampled data points, 1188
constants for making automatic
measurements, 275
constants for scaling display factors, 275
constants for setting trigger levels, 275
controller initialization, 52
copy display, 223
core commands, 1276
count, 1098
count totalize, gating enable/disable, 295
count values, 234
count, averaged value math function,
370
count, averages, FFT function, 347
count, Edge Then Edge trigger, 1023
count, Nth edge of burst, 1027
counter, 288, 465
counter commands, 287
counter mode, 291
counter source, 293
counter totalize, clear, 294
counter totalize, gating polarity, 296
counter totalize, gating signal source, 297
counter totalize, slope, 298
counter, digits of resolution, 292
counter, enable/disable, 290
coupling, 1032
COUPling demo signal, 303
coupling for channels, 269
CRC format, SENT, 821
create automask, 555
crest factor, 532
CSV (Comma Separated Values) waveform
data format, 691
cumulative edge activity, 1182
current harmonics analysis fail count, 601
current harmonics analysis results,
save, 681
current harmonics analysis run count, 604
current harmonics analysis, apply, 598
current harmonics results data, 599
current harmonics results display, 600
current logic levels on digital
channels, 195
current oscilloscope configuration, 175,
179, 183, 991
current probe, 284, 343
CURRent segment waveform save
option, 694
current source, 641
cursor mode, 429
cursor position, 428, 430, 432, 434, 437,
439
cursor readout, 1204, 1208, 1209
cursor reset conditions, 180
, 987
cursor source, 431, 433
cursor time, 1204, 1208, 1209
cursor units, X, 435, 436
cursor units, Y, 440, 441
cursor values, saving, 684
cursors track measurements, 498
cursors, how autoscale affects, 197
cursors, X1, X2, Y1, Y2, 426
cycle count base, FLEXray frame
trigger, 763
cycle count repetition, FLEXray frame
trigger, 764
cycle measured, 478, 481
cycle time, 488
cycles analyzed, number of, 625, 626
D
data, 789, 791, 1099
data (waveform) maximum length, 693
data 2, 792
data acquisition types, 1091
data conversion, 1093
data format for transfer, 1094
data output order, 1097
data pattern length, 741, 808
data pattern, ARINC 429 trigger, 714, 923
data pattern, CAN trigger, 739
data point index, 1121
data points, 236
data record, measurement, 1104
data record, raw acquisition, 1104
data required to fill time buckets, 233
DATA source, I2S, 774
data source, setup and hold trigger, 1064
data structures, status reporting, 1243
data, saving and recalling, 316
date, calibration, 257