Command Manual – System Management
Quidway S8500 Series Routing Switches Chapter 3 Device Management Commands
Huawei Technologies Proprietary
3-11
undo temperature-limit slot
View
User view
Parameter
slot: Physical card number.
down-value: Lower temperature limit, in the range 0 to 70 °C.
up-value: Upper temperature limit, in the range 20 to 90 °C.
Description
Use the temperature-limit command to configure temperature limit.
Use the undo temperature-limit command to restore temperature limit to default
value.
Example
# Set the lower and upper temperature limit of card 0.
<Quidway> temperature-limit 0 10 75
3.1.15 update l3plus
Syntax
update l3plus slot slot-no filename file-name ftpserver server-name username
user-name password password [ port port-num ]
View
System view
Parameter
slot-no: Slot for the service processing board to be updated.
file-name: Name of upgrading file to be downloaded. The file suffix is .app.
server-name: IP address or host name of FTP Server where the file to be updated
locates.
user-name: User name for file transfer protocol (FTP) login.
password: User password for FTP login.
port-num: FTP port number, in the range 0 to 65,535. By default, it is 21.
Description
Use the update l3plus command to update service processing boards. After the
command is executed, the system logs into an FTP Server with the host name, user