EasyManuals Logo

Huawei Quidway S8500 Series User Manual

Huawei Quidway S8500 Series
1341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #969 background imageLoading...
Page #969 background image
Command Manual – Reliability
Quidway S8500 Series Routing Switches Chapter 2
HA Configuration Commands
Huawei Technologies Proprietary
2-3
undo slave auto-update config
View
System view
Parameter
None
Description
Use the slave auto-update config command to enable automatic synchronization
between the master and slave systems.
Use the undo slave auto-update config command to disable automatic
synchronization between the master and slave systems.
By default, automatic synchronization is enabled.
Related command: slave update config.
Example
# Enable automatic synchronous switch between master/slave systems.
[Quidway] slave auto-update config
2.1.5 slave restart
Syntax
slave restart
View
User view
Parameter
None
Description
Use the slave restart command to restart slave board.
When the slave system works abnormally, and needs to be reloaded, you can use this
command to restart the slave board.
Example
# Implement the restart of the slave system.
<Quidway> slave restart
The slave will reset! Continue?[Y/N]:y

Table of Contents

Other manuals for Huawei Quidway S8500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S8500 Series and is the answer not in the manual?

Huawei Quidway S8500 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S8500 Series
CategorySwitch
LanguageEnglish

Related product manuals