Command Manual – Port
Quidway S8500 Series Routing Switches Chapter 3 POS Port Configuration Commands
Huawei Technologies Proprietary
3-1
Chapter 3 POS Port Configuration Commands
3.1 POS Port Configuration Commands
3.1.1 clock
Syntax
clock { master | slave }
undo clock
View
POS port view
Parameter
master: Sets the POS port to use internal clock.
slave: Sets the POS port to use line clock.
Description
Use the clock command to set clock mode at the POS port.
Use the undo clock command to restore the default clock mode at the POS port.
By default, a POS port works in the line clock mode.
Example
# Set the clock mode of POS2/1/1 to the master clock mode.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] interface pos2/1/1
[Quidway-Pos2/1/1] clock master
3.1.2 crc
Syntax
crc { 16 | 32 }
undo crc