Command Manual – Getting Started
Quidway S8500 Series Routing Switches Chapter 1
Commands Used to Log in to Switch
Huawei Technologies Proprietary
1-4
Example
# Configure the precedence of the command "interface" as 0.
<Quidway>system-view
System View: return to User View with Ctrl+Z.
[Quidway] command-privilege level 0 view system interface
1.1.4 databits
Syntax
databits { 7 | 8 }
undo databits
View
User interface view
Parameter
7: Sets 7 data bits.
8: Sets 8 data bits.
Description
Use the databits command to configure the data bits for the user interface.
Use the undo databits command to restore the default bits of the user interface.
This command can only be performed in Console and AUX user interface view.
By default, the value is 8.
Example
# Configure the data bits of AUX port to 7 bits.
<Quidway>system-view
System View: return to User View with Ctrl+Z.
[Quidway] user-interface aux 0
[Quidway-ui-aux0] databits 7
1.1.5 display history-command
Syntax
display history-command { Command-Number } { | { begin | include | exclude }
Match-string }
View
Any view

Table of Contents

Other manuals for Huawei Quidway S8500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S8500 Series and is the answer not in the manual?

Huawei Quidway S8500 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S8500 Series
CategorySwitch
LanguageEnglish

Related product manuals