Command Manual – Port
Quidway S8500 Series Routing Switches Chapter 4 RPR Port Configuration Commands
Huawei Technologies Proprietary
4-25
View
PRP logical port view
Parameter
atd value: Ranges from 1 to 10 (in seconds).
fdd value: Ranges from 10 to 1,000 (in milliseconds).
holdoff value: Ranges from 0 to 200 (in milliseconds), in steps of 10 milliseconds.
stability value: Ranges from 10 to 100 (in milliseconds), in steps of 1 millisecond.
tp-fast value: TP fast timer value, in the range of 1 to 20 (in milliseconds).
tp-slow value: TP slow timer value, in the range of 50 to 1,000 (in milliseconds).
tc-fast value: TC fast timer value, in the range of 1 to 20 (in milliseconds).
tc-slow value: TC slow timer value, in the range of 50 to 1,000 (in milliseconds).
wtr value : WTR timer value, in the range of 0 to 1,440 (in seconds). By default, it is 10
seconds.
Description
Use the rpr timer atd command to set the value of the timer for sending ATD frames
and other frames periodically. The value range is 1 to 10 (in seconds). The default value
is 1 second.
Use the undo rpr timer command to restore the default timer value.
Example
# Set the timer for sending ATD frames to 3 seconds.
<Quidway> system-view
[Quidway] interface RPR2/1/1
[Quidway-RPR2/1/1] rpr timer atd 3
4.1.25 rpr weight
Syntax
rpr weight { ringlet0 | ringlet1 } value
undo rpr weight { ringlet0 | ringlet1 }
View
RPR logical port view
Parameter
ringlet0: Configures node weight on Ringlet0.
Ringlet1: Configures node weight on Ringlet1.