Command Manual – PoE 
Quidway S8500 Series Routing Switches  Chapter 2  PoE PSU Supervision Commands
 
Huawei Technologies Proprietary 
2-1 
command 
Chapter 2  PoE PSU Supervision Commands 
2.1  PoE PSU Supervision Display Commands 
2.1.1  display poe-power ac-input state 
Syntax 
display poe-power ac-input state 
View 
Any view 
Parameter 
None 
Description 
Use the display poe-power ac-input state command to display the AC input state of 
each power supply unit (PSU). 
Example 
# Display the AC input state of each PSU. 
<Quidway> display poe-power ac-input state 
PSU 1 AC Input State : Lack Phase 
PSU 2 AC Input State : Normal 
PSU 3 AC Input State : Lack Phase 
Table 2-1 Description on the fields of the display poe-power ac-input state 
Field  Description 
NORMAL  The AC input is normal.
 
Under Limit
 
The AC input is below the lower threshold.
 
Upper Limit
 
The AC input is above the upper threshold.
 
Lack Phase  The AC input is lack of phase.
 
Fuse Broken
 
The fuse is blown.
 
Switch Off
 
The switch is off.