Command Manual – Routing Protocol
Quidway S8500 Series Routing Switches Chapter 4 Integrated IS-IS Configuration Commands
Huawei Technologies Proprietary
4-37
[Quidway-isis] timer lsp-max-age 1500
4.1.44 timer lsp-refresh
Syntax
timer lsp-refresh seconds
undo timer lsp-refresh
View
IS-IS view
Parameter
seconds: Specifies the LSP refreshment interval, measured in seconds. The range is 1
to 65535. The default value is 900 seconds.
Description
Use the timer lsp-refresh command to configure the refreshment interval of LSP.
Use the undo timer lsp-refresh command to restore the default value, that is, 900
seconds.
By this mechanism, the latest synchronization of the LSP within the entire area can be
maintained.
Related command: timer lsp-max-age.
Example
# Set the LSP refresh interval of the current system to 1500 seconds.
[Quidway-isis] timer lsp-refresh 1500
4.1.45 timer spf
Syntax
timer spf x y z [ level-1 | level-2 ]
undo timer [ level-1 | level-2 ]
View
IS-IS view
Parameter
x: Maximum interval (in seconds) for SPF calculation. It ranges from 1 to 120 and
defaults to 10.