Page #1138 background imageLoading...
Page #1138 background image
Command Manual – System Management
Quidway S8500 Series Routing Switches Chapter 7 NTP Configuration Commands
Huawei Technologies Proprietary
7-4
7.1.4 display ntp-service trace
Syntax
display ntp-service trace
View
Any view
Parameter
None
Description
Use the display ntp-service trace command to display the brief information about
every NTP server on the way from the local device to the reference clock source.
With this command, the system synchronizes the NTP server link from the local device
along time till the reference clock source, and displays brief information about every
NTP server.
Example
# Display brief information about every NTP server on the way from the local device to
the reference clock source.
<Quidway> display ntp-service trace
server 127.0.0.1,stratum 8, offset 0.000000, synch distance 0.00000
refid 127.127.1.0
7.1.5 ntp-service access
Syntax
ntp-service access { query | synchronization | server | peer } acl-number
undo ntp-service access { query | synchronization | server | peer }
View
System view
Parameter
query: Allows to control query authority.
synchronization: Only allows the server to access.
server: Allows query to server and access.
peer: Full access authority.
acl-number: IP address list number.

Table of Contents

Other manuals for Huawei Quidway S8500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S8500 Series and is the answer not in the manual?

Huawei Quidway S8500 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S8500 Series
CategorySwitch
LanguageEnglish

Related product manuals