Command Manual – System Management
Quidway S8500 Series Routing Switches Chapter 6 RMON Configuration Commands
Huawei Technologies Proprietary
6-6
Use the display rmon prialarm command to view information about extended RMON
alarm table.
Related command: rmon prialarm.
Example
# Display the information about extended RMON alarm table.
<Quidway> display rmon prialarm
Prialarm table 1 owned by monitor is UNDERCREATION.
Samples type : changeratio
Variable formula :
(.1.3.6.1.2.1.2.2.1.10.201326601+.1.3.6.1.2.1.2.2.1.16
.201326601)*8*100/.1.3.6.1.2.1.2.2.1.5.201326601
Description : ifUtilization.Ethernet5/1/1
Sampling interval : 10(sec)
Rising threshold : 50(linked with event 1)
Falling threshold : 5(linked with event 1)
When startup enables : risingOrFallingAlarm
This entry will exist : forever.
Latest value : 0
Table 6-5 Description on the fields of the display rmon prialarm command
Field Description
Prialarm table 1 Index of extended alarm entry.
owned by monitor Creator of the extended alarm entry.
UNDERCREATION Status of expansion alarms
Samples type Type of sampling
Variable formula Formula for expansion alarms
Description Description information
Sampling interval :
10(sec)
Sampling interval
Rising threshold
Rising threshold. When sampling value rises from
normal value to this threshold, rising threshold alarm will
be triggered.
Falling threshold
Falling threshold. When sampling value decreases from
normal value to this threshold, falling threshold alarm will
be triggered.
linked with event 1
Corresponding event index of ring and falling threshold
alarm.
When startup enables:
risingOrFallingAlarm
Kind of first alarm. It may trigger rising threshold alarm or
falling threshold alarm or both.