Command Manual – System Management
Quidway S8500 Series Routing Switches Chapter 6 RMON Configuration Commands
Huawei Technologies Proprietary
6-12
Parameter
entry-number: Specifies the entry number, ranging from 1 to 65535.
prialarm-formula: Variables in the formula must be represented by OID, for example,
(1.3.6.1.2.1.2.1.10.1)*8. The operation results are in long integers. Every operation
result must be within the range of the long integer; otherwise, errors may be prompted.
prialarm-des : Specifies the alarm description with a length ranging from 1 to 256;
sampling-timer: Sets the sampling interval, ranging from 10 to 65535 and measured in
seconds.
delta | absolute | changeratio: Specifies the sampling type as delta ratio, absolute
ratio or change ratio.
threshold-value1: Rising threshold value, specified with a number greater than 0.
event-entry1: Corresponding event number to the upper limit threshold value, ranging
from 0 to 65535.
threshold-value2: Falling threshold value, specified with a number greater than 0.
event-entry2: Event number corresponding to the falling threshold, ranging from 0 to
65535.
forever | cycle cycle-period: Specifies the type of the alarm instance line.
cycle-period specifies the functional cycle of the instance.
owner text: Creator of this entry. Length of the character string ranges from 1 to 127.
Description
Use the rmon prialarm command to add an entry to the extended RMON alarm table.
Use the undo rmon prialarm command to cancel an entry from the extended RMON
alarm table.
The number of instances can be created in the table depends on the hardware
resource of the product.
 Note:
Before adding an extended alarm entry, you need first to define the event to be
referenced in the extended alarm entry using the rmon event command.
You can define up to 50 prialarm entries.
The system takes these actions on the extended alarm entries you defined:
z Sampling the alarm variables in the defined extended alarm formula at a specified
time interval.
z Calculating the sample value using the defined extended alarm formula.

Table of Contents

Other manuals for Huawei Quidway S8500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S8500 Series and is the answer not in the manual?

Huawei Quidway S8500 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S8500 Series
CategorySwitch
LanguageEnglish

Related product manuals