MPU Registers
www.ti.com
102
SPRUH91D–March 2013–Revised September 2016
Submit Documentation Feedback
Copyright © 2013–2016, Texas Instruments Incorporated
Memory Protection Unit (MPU)
5.3.15 Fault Clear Register (FLTCLR)
The fault clear register (FLTCLR) allows software to clear the current fault so that another can be captured
in the fault status register (FLTSTAT) as well as produce an interrupt. Only the TYPE bit field in FLTSTAT
is cleared when a 1 is written to the CLEAR bit. The FLTCLR is shown in Figure 5-19 and described in
Table 5-22.
Figure 5-19. Fault Clear Register (FLTCLR)
31 16
Reserved
R-0
15 1 0
Reserved CLEAR
R-0 W-0
LEGEND: R = Read only; W = Write only; -n = value after reset
Table 5-22. Fault Clear Register (FLTCLR) Field Descriptions
Bit Field Value Description
31-1 Reserved 0 Reserved
0 CLEAR Command to clear the current fault. Writing 0 has no effect.
0 No effect.
1 Clear the current fault.